Further inquiries
To locate specific information or resolve questions after reviewing this guide contact Crestron’s
True Blue support at 1-888-CRESTRON [1-888-273-7876] or refer to the listing of Crestron
worldwide offices on the Crestron Web site (http://www.crestron.eu/?q=en/contact/global_offices)
for assistance within a particular geographic region.
To post questions about Crestron products log onto the Online help section of the Crestron Web
site (www.crestron.com/onlinehelp). First-time users must establish a user account to fully benefit
from all available features.
DESCRIPTION
The TSW-750-FMKT flush mount kit is an optional accessory for use with a Crestron® TSW-750 7”
touch screen. It is designed for a in-wall flush installation of a TSW-750 touch screen onto a
concrete/brick wall and drywall. The TSW-750-FMKT securely mounts the touch screen while allow-
ing easy access, insertion and exertion by manual push and magnet detachment of the touch screen
tray. When installing the TSW-750-FMKT onto a concrete/brick wall first install the TSW-750-FMKT-
BBI brick wall back box for a professional installation. The mounting kit is configured for installation
in 12.7mm (1/2 inch) thick clad constructions, shimming may be required if adjacent material is not
12.7 mm drywall (1/2 inch). Installations and finishes are in the same manner as drywall.
Specications Details
Material MDF
Dimensions
Height
Width
Depth
190.5 mm (7.5”)
264 mm (10.4”)
16.6 mm (0.65”)
Weight 0.3 kg (0.7 pounds)
Available Models
TSW-750-FMKT TSW-750 Flush Mount Kit
Physical View - Front side and Rear
Cut and Place
First determine where the TSW-750-FMKT mount will be located, keeping in mind that the
TSW-750-FMKT mounts need to fit between two studs. To locate these studs use a stud finder
(We suggest using a high quality stud finder that can detect studs, AC cables and water pipes so
that you can avoid these in-wall obstacles).
When a favourable installation position is determined, drill a pilot hole in the middle. USE CAUTION
when drilling, not to plunge into a pipe or electrical conduit. When the hole is drilled, explore the
surrounding area, making sure there are no obstacles present and that there’s enough room for
the mount. While using the mount, a level and a pencil, mark the top and bottom horizontal edges
of the mount on the drywall. Continue each line to the closest stud centre. Cut the drywall accord-
ing the top and bottom marked lines and stud centres using a utility knife or saw. After cutting the
drywall chamfer the rim of the opening using a coarse rasp.
Route adequate cabling to the installation point in accordance with your local electric regulations.
The TSW-750-FMKT needs to fit between two studs and be installed on two horizontal supports
that are secured to the studs.
It is proffered that the TSW-750-FMKT is mounted on two horizontal supports and at least one
stud. A good choice for horizontal supports are telescoping box mounting brackets that are in-
stalled on stud face without bending their fixing plates. Horizontal supports may be made on site
of the drywall U tracks. When performing a retrofit work, insert the horizontal supports half way
under the top and bottom drywall edges of the opening. PAY ATTENTION UP / DOWN ORIENTATION
OF THE ADAPTER ACCORDING TO THE ARROWS MARKED ON THE BACK SIDES OF THE ADAPTER.
SETUP
Installation Tools and Materials
Safety goggles
Dust mask
Screwdriver
Measuring tape
Utility knife/saw
Leveller
Brush / sponge roller
Pencil
Spatula
Spackle tray
Coarse Rasp
Drywall T-square
Taping or joint knife
Sandpaper
Pole Sander
#6 bugle head screws
Setting-type compound
Drywall mud or joint compound
Drywall Paper tape
Paint
Drywall
INSTALLATION
Safety
Use a dust mask to avoid getting dust particles in you lungs
Wear eye protection to avoid getting dust particles in your eyes.
Turn off the power in areas you’ll be drilling to avoid electric shock.
Use plastic or canvas drop cloths to prevent the sanding dust from damaging nearby
furniture or spreading beyond you immediate work area.
NOTES: Observe the following points.
Use caution when installing the TSW-750-FMKT, not to plunge into a pipe or electrical
conduit.
For Low voltage use only.
Pay attention up /down orientation of the adapter according to the arrows marked on the
back sides of the adapter.
Pay attention, avoid plugging the microphone and speaker grills with excessive paint also do
not paint the internal surface.
Crestron International
Oude Keerbergesebaan 2 Rijmenam, 2820
Tel: +32.15.50.99.50
Fax: +32.15.50.99.40
www.crestron.eu
Installation Guide
Specifications subject to
change without notice
Future Updates
As Crestron improves functions, adds new features and extends the capabilities of the TSW-750-
FMKT, additional information may be made available as manual updates. These updates are solely
electronic and serve as intermediary supplements prior to the release of a complete technical
documentation revision.
Check the Crestron Web site periodically for manual update availability and its relevance. Updates
are identified as an “Addendum” in the Download column.
Page view 0
1 2

Summary of Contents

Page 1 - Installation guide

Crestron TSW-750-FMKTTSW750 Flush Mount KitInstallation guideFurther inquiriesTo locate specific information or resolve questions after reviewing this

Page 2

PaintingBefore painting, remove the protective tape from de microphone and speaker grills. PAY ATTEN-TION, AVOID PLUGGING THE MICROPHONE AND SPEAKER G

Comments to this Manuals

No comments