CAEN
Introduction
Crestron
CAEN Series automation enclosures are
designed to house Crestron's CLX-Series lighting control
modules and PAC2 or PAC2M control systems. CAEN
enclosures are available in an assortment of sizes, suitable
for surface or flush wall-mount installation. Each model
has been engineered to provide a clean and manageable
installation with abundant provisions for wire termination
and electrical knockouts.
NOTE: The PAC2 occupies two module spaces in a
double-wide enclosure and one module space in a
single-wide.
NOTE: Four keyholes are located within the enclosure
and should be used if surface mounting.
CAEN Overall Dimensions (Front and Side Views)
Functional Summary
Specifications
DIMENSIONS
1
CAEN-
7x2
CAEN-
7x1
CAEN-
4x2
CAEN-
4x1
CAEN-
2x1
H1
62 3/4
(1594)
62 3/4
(1594)
39 5/8
(1007)
39 5/8
(1007)
24 1/4
(616)
H2
2 11/16
(69)
2 11/16
(69)
2 11/16
(69)
2 1/8
(53)
2 1/8
(53)
H3
56
(1422)
56
(1422)
32 7/8
(835)
34
(863)
18 5/8
(473)
W1
27 1/4
(692)
16 1/8
(410)
27 1/4
(692)
16 1/8
(410)
15 3/8
(390)
W2
25 1/2
(648)
14 3/8
(365)
25 1/2
(648)
14 3/8
(365)
14 3/8
(365)
W3
2 1/2
(64)
1 3/4
(45)
2 1/2
(64)
1 3/4
(45)
1 3/4
(45)
W4
20 1/2
(520)
10 7/8
(276)
20 1/2
(520)
10 7/8
(276)
10 7/8
(276)
W5
2
20 1/2
(521)
9 7/8
(250)
20 1/2
(521)
9 7/8
(250)
9 7/8
(250)
W6
2 1/2
(64)
2 3/4
(69)
2 1/2
(64)
2 3/4
(69)
2 3/4
(69)
D1
4 3/16
(107)
4 3/16
(107)
4 3/16
(107)
4 1/16
(103)
4 3/16
(107)
Cover
Thickness
1/16
(1)
1/16
(1)
1/16
(1)
1/16
(1)
1/16
(1)
Cover Height
62 3/4
(1593)
62 3/4
(1593)
39 5/8
(1006)
39 5/8
(1006)
24 1/4
(615)
Cover Width
27 1/4
(692)
16 1/8
(409)
27 1/4
(692)
16 1/8
(409)
16 1/8
(409)
Weight (empty)
3
65
(29.5)
42
(19.1)
43
(19.5)
28
(12.7)
19
(8.6)
Maximum
Weight (filled)
200
(90.8)
100
(45.4)
100
(45.4)
55
(24.9)
31
(14.1)
1. Length is specified in inches and millimeters (in parentheses).
Weight is specified in pounds and kilograms (in parentheses).
2. The lower keyholes are not symmetrically spaced within single-
wide enclosures.
3. Weight (empty) is the weight of an empty enclosure with cover.
• Houses Crestron lighting modules, terminal
blocks, professional automation computer, and
third-party products with or without Crestron
universal mounting plates
• Flush or surface mounted installation
• Ventilated cover for convection cooling of
dimming modules
• Conveniently located electrical knockouts for
both Class 1 and Class 2 wiring
• 16-gauge hot dipped galvanized steel
Crestron Electronics, Inc. Installation Guide – DOC. 5940E
15 Volvo Drive Rockleigh, NJ 07647 (2002052)
Tel: 888.CRESTRON 06.14
Fax: 201.767.7576 Specifications subject to
www.crestron.com change without notice.