Crestron SIMPL+ User Manual Page 12

  • Download
  • Add to my manuals
  • Print
  • Page
    / 15
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 11
© 2008 Sooloos LLC Module Glossary
|
Page 12
Crestron
®
Module Guide
-
Module Glossary
Sooloos LLC
110 Grene Street, Suite 608
New York, NY 10012
tel: 1.866.606.0333
open_connection
When pulsed high, instructs the module to connect to the
Sooloos system specified in the ip_address module parameter.
This input should be pulsed high during program startup. It
is recommended that the Crestron processor stay connected
to the Sooloos system at all times to avoid user delays when
switching to control the Sooloos system. If multiple modules
are being used within a single processor, it is recommended
to stagger their startup by using a Stepper symbol. The
module will automatically re-connect to the Sooloos server
in case of disconnection caused by any reason other than
pulsing close_connection high.
close_connection
When pulsed high, instructs the module to close the current
connection to the Sooloos system. This input is not normally
used in programs where the Crestron processor stays con-
nected to the Sooloos system.
select_zone[1]
select_zone[2]
select_zone[5]
When pulsed high, instructs the module to switch to controlling
the Sooloos zone indicated by the corresponding zone#_id
module parameter. By default, the module controls zone1_id
after successfully connecting to a Sooloos system. Once
pulsed high, the module will request the information from the
server for the corresponding zone#_id module parameter and
will re-populate the relevant module outputs. If the correspond-
ing zone identifier is not valid, the zone_valid output will be
pulled low.
show_transport
When pulsed high, instructs the module to switch display to the
transport page. This action modifies internal state and pulses
page_transport high. Pulsing this input while the module is
currently waiting for confirm_yes or confirm_no to be pulsed
has the same effect as first raising confirm_no.
show_browse
When pulsed high, instructs the module to switch display to
the browse page. This action modifies internal state and pulses
page_browse high. Pulsing this input while the module is cur-
rently waiting for confirm_yes or confirm_no to be pulsed has
the same effect as first raising confirm_no.