Crestron CHV-RTS User Manual

Browse online or download User Manual for Thermostats Crestron CHV-RTS. Operations & Installation Guide: CHV-TSTATEX

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - Crestron CHV-TSTATEX

Crestron CHV-TSTATEX infiNET EX™ Thermostat Operations & Installation Guide

Page 2

infiNET EX™ Thermostat Crestron CHV-TSTATEX CHV-TSTATEX Overall Dimensions (Rear View) CHV-TSTATEX (Connection View, front with cover removed) 67

Page 3 - Contents

Crestron CHV-TSTATEX infiNET EX™ Thermostat Connectors, Controls & Indicators (Continued) # CONNECTORS, CONTROLS & INDICATORS DESCRIPTION 4

Page 4

infiNET EX™ Thermostat Crestron CHV-TSTATEX Setup Identity Code Every CHV-TSTATEX communicating via RF with a Crestron control system through a CEN

Page 5 - CHV-TSTATEX

Crestron CHV-TSTATEX infiNET EX™ Thermostat CAUTION: Excess wire pinched between the CHV-TSTATEX and electrical box could cause a short circuit. M

Page 6 - Easy Installation

infiNET EX™ Thermostat Crestron CHV-TSTATEX DIP Switch Setup The following describes the DIP switch settings. 1. Install two AA batteries (supplie

Page 7 - Specifications

Crestron CHV-TSTATEX infiNET EX™ Thermostat NOTE: Steal Power mode may cause problems with some types of HVAC systems, such as indicating a false

Page 8 - FTP site)

infiNET EX™ Thermostat Crestron CHV-TSTATEX NOTE: 24 Volt power is returned through the RH connector. Refer to wiring diagrams on the following pa

Page 9 - Physical Description

Crestron CHV-TSTATEX infiNET EX™ Thermostat NOTE: To run fan during heat calls, be sure to enable the DIP switches. Refer to “DIP Switch Setup” wh

Page 10

infiNET EX™ Thermostat Crestron CHV-TSTATEX CHV-TSTATEX in Heat-Cool Application with Separate Systems RS2RS1RSRRSRW2RHBOGY2Y/Y1RC24CTransformerRCC

Page 11 - DESCRIPTION

Crestron CHV-TSTATEX infiNET EX™ Thermostat CHV-TSTATEX in Heat Pump System Application with Integrated Controller RS2RS1RSRRSRW2W/W1RHBOGY2Y/Y1RC2

Page 12 - Installation

This document was prepared and written by the Technical Documentation department at: Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647

Page 13

infiNET EX™ Thermostat Crestron CHV-TSTATEX NOTE: If the system requires a fan, set the top dip switch in the right bank to “on”. CHV-TSTATEX Sens

Page 14 - DIP Switch Setup

Crestron CHV-TSTATEX infiNET EX™ Thermostat Basic Setup Basic Thermostat Setup The following describes the most common setup requirements. For full

Page 15

infiNET EX™ Thermostat Crestron CHV-TSTATEX NOTE: The acquire process can take up to 15 seconds. The acquire process cannot be aborted. NOTE: “E1

Page 16 - Optional, for power

Crestron CHV-TSTATEX infiNET EX™ Thermostat Advanced Setup Setup Mode After the CHV-TSTATEX is installed, it is necessary to set it up for a partic

Page 17 - Fan Relay

infiNET EX™ Thermostat Crestron CHV-TSTATEX NOTE: While in Setup mode, a period of one minute with no button activity will cause the CHV-TSTATEX t

Page 18

Crestron CHV-TSTATEX infiNET EX™ Thermostat Setup Mode Parameters/Functions (Continued) PARAMETER/ FUNCTION CODE VALID VALUES DEFAULT VALUE NOTES A

Page 19

infiNET EX™ Thermostat Crestron CHV-TSTATEX Setup Mode Parameters/Functions (Continued) PARAMETER/ FUNCTION CODE VALID VALUES DEFAULT VALUE NOTES U

Page 20 - CHV-TSTATEX Sensor Wiring

Crestron CHV-TSTATEX infiNET EX™ Thermostat Operation System Mode The MODE button on the CHV-TSTATEX will cycle the unit through all available syst

Page 21 - Basic Setup

infiNET EX™ Thermostat Crestron CHV-TSTATEX indicates which setpoint will be adjusted by subsequent presses of the or buttons. To adjust or view

Page 22

Crestron CHV-TSTATEX infiNET EX™ Thermostat Setpoints The setpoint is the user selectable temperature you want the system to maintain. The and b

Page 23 - Advanced Setup

Crestron CHV-TSTATEX infiNET EX™ Thermostat Contents infiNET EX™ Thermostat: CHV-TSTATEX 1 Introduction ...

Page 24

infiNET EX™ Thermostat Crestron CHV-TSTATEX Remote Operation As an infiNET EX device, the CHV-TSTATEX can be controlled remotely via a Crestron con

Page 25

Crestron CHV-TSTATEX infiNET EX™ Thermostat LCD Display Elements # LCD DISPLAY ELEMENT DESCRIPTION 1 Large seven-segment digits Indicates current a

Page 26

infiNET EX™ Thermostat Crestron CHV-TSTATEX Programming Software Have a question or comment about Crestron software? Answers to frequently asked q

Page 27 - Operation

Crestron CHV-TSTATEX infiNET EX™ Thermostat Programming with SIMPL Windows NOTE: While SIMPL Windows can be used to program the CHV-TSTATEX, it is

Page 28

infiNET EX™ Thermostat Crestron CHV-TSTATEX C2Net Device, Slot 8 2. If additional CHV-TSTATEX devices are to be added, repeat step 1b for each de

Page 29 - Setpoints

Crestron CHV-TSTATEX infiNET EX™ Thermostat Uploading and Upgrading Crestron recommends using the latest programming software and that each device

Page 30 - LCD Display

infiNET EX™ Thermostat Crestron CHV-TSTATEX Upgrade CHV-TSTATEX firmware via Crestron Toolbox. 1. Establish communications with the CHV-TSTATEX an

Page 31 - ELEMENT

Crestron CHV-TSTATEX infiNET EX™ Thermostat Problem Solving Troubleshooting The following table provides corrective action for possible trouble sit

Page 32 - Programming Software

infiNET EX™ Thermostat Crestron CHV-TSTATEX CHV-TSTATEX Troubleshooting (Continued) TROUBLE POSSIBLE CAUSE(S) CORRECTIVE ACTION Using the 24V posi

Page 33

Crestron CHV-TSTATEX infiNET EX™ Thermostat CHV-TSTATEX Troubleshooting (Continued) TROUBLE POSSIBLE CAUSE(S) CORRECTIVE ACTION Steal power functi

Page 35 - Uploading and Upgrading

infiNET EX™ Thermostat Crestron CHV-TSTATEX Appendix: About Heat Pumps A heat pump extracts available heat from one area and transfers it to anothe

Page 36 - Program Checks

Crestron CHV-TSTATEX infiNET EX™ Thermostat Glossary Anticipators Used to anticipate the drop or rise in temperature and energize the appropriate s

Page 37 - Problem Solving

infiNET EX™ Thermostat Crestron CHV-TSTATEX Humidity The total amount of moisture in air. Relative humidity (RH) is the amount of moisture in air,

Page 38 - CORRECTIVE ACTION

Crestron CHV-TSTATEX infiNET EX™ Thermostat Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise may be returned fo

Page 39 - Future Updates

Crestron Electronics, Inc. Operations & Installation Guide – DOC. 6989A 15 Volvo Drive Rockleigh, NJ 07647 (2027560) Tel: 888.CRESTRON

Page 40 - Appendix: About Heat Pumps

Crestron CHV-TSTATEX infiNET EX™ Thermostat infiNET EX™ Thermostat: CHV-TSTATEX infiNET EX™ Thermostat: CHV-TSTATEX Introduction Introduction The

Page 41 - Glossary

infiNET EX™ Thermostat Crestron CHV-TSTATEX Heat/Cool Thermostat The CHV-TSTATEX is designed for heating and cooling control of baseboard, forced a

Page 42

Crestron CHV-TSTATEX infiNET EX™ Thermostat Specifications Specifications for the CHV-TSTATEX are listed in the following table. CHV-TSTATEX Specif

Page 43 - Return and Warranty Policies

infiNET EX™ Thermostat Crestron CHV-TSTATEX CHV-TSTATEX Specifications (Continued) SPECIFICATION DETAILS Default RFID 01 Minimum 2-Series Control

Page 44

Crestron CHV-TSTATEX infiNET EX™ Thermostat Physical Description This section provides information on the connections, controls and indicators avai

Comments to this Manuals

No comments