Crestron QM-FTDC QuickMedia™ FlipTop Data Center Operations & Installation Guide
FlipTop Data Center Crestron QM-FTDC QM-FTDC Specifications (Continued) SPECIFICATION DETAILS Weight (Domestic Models) 4.05 lbs (1.84 kg) Weight (
Crestron QM-FTDC FlipTop Data Center Physical Description This section provides information on the connections, controls and indicators available o
FlipTop Data Center Crestron QM-FTDC QM-FTDC-NB (Top View) NOTE: The physical dimensions of the NB models are identical to the models with keyp
Crestron QM-FTDC FlipTop Data Center QM-FTDC (Bottom View) QMI-FTDC (Bottom View) QM-FTDC Overall Dimensions (Rear View) QMI-FTDC Overall Dimen
FlipTop Data Center Crestron QM-FTDC QM-FTDC Overall Dimensions (Side View) QMI-FTDC Overall Dimensions (Side View) 4.64 in11.77 cm5.21 in13.23 c
Crestron QM-FTDC FlipTop Data Center Connectors, Controls & Indicators # CONNECTORS1, CONTROLS & INDICATORS DESCRIPTION 1 KEYPAD2 Programma
FlipTop Data Center Crestron QM-FTDC Connectors, Controls & Indicators (Continued) # CONNECTORS1, CONTROLS & INDICATORS DESCRIPTION 9 LAN 8
Crestron QM-FTDC FlipTop Data Center Connectors, Controls & Indicators (Continued) # CONNECTORS1, CONTROLS & INDICATORS DESCRIPTION 14 MIC/
FlipTop Data Center Crestron QM-FTDC 5. The eight-pin RJ-45 QuickMedia transport port accepts CAT5E/CAT6 carrying audio, video and microphone sign
Crestron QM-FTDC FlipTop Data Center Industry Compliance This product (QM- only) is Listed to applicable UL Standards and requirements by Underwrit
This document was prepared and written by the Technical Documentation department at: Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647
FlipTop Data Center Crestron QM-FTDC Setup Network Wiring When wiring the network, consider the following: • Use Crestron Certified Wire. • Use
Crestron QM-FTDC FlipTop Data Center The aggregate cable length of a signal path originating at a QM-FTDC and terminating at a QM receiver must not
FlipTop Data Center Crestron QM-FTDC Installation NOTE: To prevent overheating, do not operate this product in an area that exceeds the environmen
Crestron QM-FTDC FlipTop Data Center Button Installation QM-FTCMK Cable Management Plate The QM-FTDC is shipped with a blank bottom plate. A cable
FlipTop Data Center Crestron QM-FTDC 5. Feed all the excess cable through the opening. 6. Attach the plate using the four #4 x ¼ LG black mountin
Crestron QM-FTDC FlipTop Data Center NOTE: Ensure that the cables have sufficient clearance to enable smooth movement. Allow approximately 40 inch
FlipTop Data Center Crestron QM-FTDC Mounting Bracket Screw Locations 3. Install the four #10 screws in the mounting brackets (two screws per bra
Crestron QM-FTDC FlipTop Data Center NOTE: Be careful not to press the buttons while closing the FlipTop, even though the buttons are disabled whe
FlipTop Data Center Crestron QM-FTDC gauge used in interconnecting cables. The ratings on the connecting unit's supply input should be conside
Crestron QM-FTDC FlipTop Data Center Configuration Software Have a question or comment about Crestron software? Answers to frequently asked questi
Crestron QM-FTDC FlipTop Data Center Contents QuickMedia™ FlipTop Data Center: QM-FTDC 1 Introduction ...
FlipTop Data Center Crestron QM-FTDC Configuring with SIMPL Windows NOTE: While SIMPL Windows can be used to program the QM-FTDC, it is recommende
Crestron QM-FTDC FlipTop Data Center • If necessary, double click a device to open the “Device Settings” window and change the Net ID, as shown in
FlipTop Data Center Crestron QM-FTDC Example Program An example program for the QM-FTDC is available from the Crestron website (http://www.crestron
Crestron QM-FTDC FlipTop Data Center Visual Representation of Gating Level, Clipping Level, Attack Time and Decay Time Clipping LevelGating LevelAt
FlipTop Data Center Crestron QM-FTDC 1. To adjust the input gain, set the gain and noise gate to their lowest settings. Disable the “Mute” functio
Crestron QM-FTDC FlipTop Data Center Uploading and Upgrading Crestron recommends using the latest programming software and that each device contain
FlipTop Data Center Crestron QM-FTDC Program Checks Using Crestron Toolbox, display the network device tree (Tools | Network Device Tree) to show a
Crestron QM-FTDC FlipTop Data Center Problem Solving Troubleshooting The following table provides corrective action for possible trouble situation
FlipTop Data Center Crestron QM-FTDC QM-FTDC Troubleshooting (Continued) TROUBLE POSSIBLE CAUSE(S) CORRECTIVE ACTION Microphone requires phantom
Crestron QM-FTDC FlipTop Data Center chained on the run, the Cresnet power usage of each network unit to be daisy-chained must be added together to
FlipTop Data Center Crestron QM-FTDC You can also log onto the online help section of the Crestron website to ask questions about Crestron products
Crestron QM-FTDC FlipTop Data Center Appendix A: International Receptacles PART NUMBER DESCRIPTION COUNTRIES 6003287 6501271 PWR-AU-B POWER RECEPT
FlipTop Data Center Crestron QM-FTDC Appendix B: QuickMedia Installation and Compensation Installation Notes You must pass audio through from tra
Crestron QM-FTDC FlipTop Data Center Auto Compensation with a Self-Peaking Receiver Crestron's innovative self-peaking audio circuit eliminate
FlipTop Data Center Crestron QM-FTDC Compatibility Charts Under certain circumstances, the audio and video may be acceptably peaked even though the
Crestron QM-FTDC FlipTop Data Center KEY: = Good operation. 1. = Operation depends on video rates and if the audio and video cable lengths are cl
FlipTop Data Center Crestron QM-FTDC Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise may be returned for cred
Crestron QM-FTDC FlipTop Data Center This page is intentionally left blank. Operations & Installation Guide – DOC. 6312B FlipTop Data Center:
Crestron Electronics, Inc. Operations & Installation Guide – DOC. 6312B 15 Volvo Drive Roc
Crestron QM-FTDC FlipTop Data Center QuickMedia™ FlipTop Data Center: QM-FTDC Introduction Features and Functions The QM-FTDC FlipTop Data Center i
FlipTop Data Center Crestron QM-FTDC Features and Functions (Continued) • Two mic inputs with phantom power (on the bottom) • One QuickMedia™ RJ
Crestron QM-FTDC FlipTop Data Center NOTE: For QuickMedia wiring use CresCAT-QM, CresCAT-IM or quality Cat5e/CAT6 cable. The maximum aggregate cab
FlipTop Data Center Crestron QM-FTDC Internal Block Diagram The following diagram represents the interfacing abilities of the QM-FTDC. This Cresnet
Crestron QM-FTDC FlipTop Data Center Specifications Specifications for the QM-FTDC are listed in the following table. QM-FTDC Specifications SPECIF