Professional Audio Distribution Processor Crestron CNX-PAD8A
The CNX-PAD8A receives signals from the previously discussed symbols. The
CNX-PAD8A receives (E) audio from the selected source, signals to illuminate the
front panel LED for Room 1 when it is enabled to receive audio, the audio volume
level and mute signal. The remaining inputs (G) are not used in the CNX-PAD8A
basic program.
Detail View of CNX-PAD8A Symbol (ID-44) in SIMPL Windows’ Programming Manager
Problem Solving
Troubleshooting
The table below provides corrective action for possible trouble situations. If further
assistance is required, please contact a Crestron customer service representative.
CNX-PAD8A Troubleshooting
TROUBLE
POSSIBLE
CAUSE(S)
CORRECTIVE ACTION
PWR LED does
not illuminate.
CNX-PAD8A is not
receiving power.
Verify that cable plugged into NET port is
secure.
NET LED does
not illuminate.
Loose network
connection.
Verify that cables plugged into NET port is
secure.
Improper NET ID. Verify that CNX-PAD8A NET ID matches NET
ID software program. Refer to "Identity Code".
ROOM 1-8 LED
does not
illuminate.
Improper
programming.
Confirm signal names and programming logic
so that LEDs respond when functions are
activated.
Hum on audio. Grounding problem. Either connect or remove chassis ground wire.