Crestron TPMC-8L Isys i/O™ 8.4” Touchpanel Media Center
“Configure Network Connection” Window
To add a network drive, touch
to browse for the new network connection.
1. Map this connection by selecting a drive letter from the Map Drive Letter
drop box.
2. Enter a User Name and Password.
3. Touch the Remember and reconnect on startup checkbox if so desired.
4. Touch OK to enable the new network connection and return to the
“Network Connections” window.
Once all changes to network connections have been completed, touch OK to return
to the setup menu.
Touch Screen
When Touch Screen is touched, the calibration screen will be displayed. Touch the
screen to begin the calibration process. If the screen is not touched within 10
seconds, the calibration sequence will stop and the screen will again display the
setup menu.
If the screen is touched within the 10-second timeout, it displays a series of messages
indicating that you should touch the red square in five places around the screen.
These messages will appear sequentially starting with “Touch the red square” at the
top of the screen toward the upper left corner. Touch and hold the center of the red
square to initiate calibration. The message will say “Hold…” for a few seconds, then
change to “Lift off to proceed”. Touch the displayed squares as prompted
everywhere they appear around the screen until the calibration is complete and you
are returned to the setup menu.
NOTE: When touching the screen during calibration, be as accurate as possible.
Use the tip of the included stylus. To cancel calibration and return to the setup menu
without saving calibration data, ignore the “Touch the red square” message. After
about 10 seconds, the setup menu will be displayed. If a USB keyboard is attached to
the touchpanel, you can also press the Escape key (Esc) to cancel calibration and
return to the setup menu.
NOTE: The touchpanel’s calibration routine can also be accessed through Crestron
Toolbox if the touchpanel is connected to a control system via TCP/IP. From the
System Info page, select Functions | Setup Mode…. Select Enter Calibration
Mode to begin calibration.