Digital Video Processor Crestron C2N-DVP4DI
Ethernet touchpanels. To add a device to the system expand the C2ENET-1 slot and
double-click the desired IP ID, or right-click and select Add Item from the submenu.
Then select the device you want to add.
In Program Manager, the C2ENET-1 symbol contains no signals; to program a
controlled Ethernet device, expand the C2ENET-1 symbol in Program View. Then
drag the symbol to Detail View. (Alternatively, you can double-click the symbol.)
Slot 5: Front Panel
Slot 5 is a physical representation of the built-in front panel. No programming is
required.
Remote Processing Mode (Slave Mode)
In the Remote Processing mode, the C2N-DVP4DI does not contain a main control
system program. The program is installed in another 2-Series control system acting
as the host. The slots and Cresnet devices are accessed solely from the host control
system that generates all the proper network packets to control the hardware. For
example, to utilize a C2N-DVP4DI as a peripheral for a PRO2, C2N-DVP4DI
Remote Cresnet Processing is dropped on the C2Net slot (09) of the PRO2. The
C2N-DVP4DI device appears in the Program View as ID 54 as shown in the
following illustration.
Remote Processing Mode C2N-DVP4DI in SIMPL Windows’ Program View of the PRO2
When adding other devices to the system, right-click the device symbol in System
View, select Configure, the Net ID tab, and select or enter the desired Net ID.
Slot 2: C2I-COM5-232 of ID 54 contains Ports A-E, C2N-DVP4DI Two-way serial
drivers (A-D are for Com 1-4 ports, E is for Touchscreen/Mouse port). To change
RS-232 settings, double-click on a port to open the “Device Settings” window.
Slot 2: C2I COM5-232
Reference Guide – DOC. 6177A
32 Contents