16-Port Managed PoE Switch Crestron CEN-SWPOE-16
6
16-Port Managed PoE Switch: CEN-SWPOE-16 Operations Guide DOC. 7408B
Setup
Network Wiring
When wiring the Ethernet network, consider the following:
Use Crestron Certified Wire.
Use Crestron power supplies for Crestron equipment.
Provide sufficient power to the system.
CAUTION: Insufficient power can lead to unpredictable results or damage
to the equipment. Please use the Crestron Power Calculator to help calculate
how much power is needed for the system (
www.crestron.com/calculators).
CAT5 Wiring
Category 5 (CAT5) wiring is a twisted pair cable designed for Ethernet networks.
These networks operate at speeds of up to 1000 megabits per second (Mbps) using
the 1000BASE-T standard. For more information refer toAppendix: Fast Ethernet
and Gigabit Ethernet” on page 22.
For additional information, refer to the latest version of the Crestron CAT5 Wiring
Reference Guide (Doc. 6137), which is available from the Crestron Web site
(www.crestron.com/manuals
).
Installation
NOTE: If power needs to be removed from this product, the power cord must be
disconnected; therefore, the socket-outlet must be installed near the equipment and
must be easily accessible.
Ventilation
The CEN-SWPOE-16 should be used in a well-ventilated area. The venting holes
should not be obstructed under any circumstances.
To prevent overheating, do not operate this product in an area that exceeds the
environmental temperature range listed in the table of specifications. Consider using
forced air ventilation and/or incrementing the spacing between units to reduce
overheating. Consideration must be given if installed in a closed or multi-unit rack
assembly since the operating ambient temperature of the environment may be greater
than the room ambient temperature. Contact with thermal insulating materials should
be avoided on all sides of the unit.
NOTE: Installation of the equipment in a rack should be such that the amount of air
flow required for safe operation of the equipment is not compromised.
Rack Mounting
The CEN-SWPOE-16 can be mounted in a rack or stacked with other equipment.
Two “ears” are provided with the CEN-SWPOE-16 so that the unit can be rack
mounted. These ears must be installed prior to mounting. Complete the following
procedure to attach the ears to the unit. The only tool required is a #1 or #2 Phillips
screwdriver.