Crestron CEN-SWPOE-16 16-Port Managed PoE Switch
Operations Guide DOC. 7408B 16-Port Managed PoE Switch: CEN-SWPOE-16
7
WARNING: To prevent bodily injury when mounting or servicing this unit in a
rack, observe the following guidelines:
When mounting this unit in a partially filled rack, load the rack from the
bottom to the top with the heaviest component at the bottom of the rack.
If the rack is provided with stabilizing devices, install the stabilizers before
mounting or servicing the unit in the rack.
NOTE: If rack mounting is not required, rubber feet are provided for tabletop
mounting or stacking. Apply the feet near the corner edges on the underside of the
unit.
NOTE: Reliable earthing of rack-mounted equipment should be maintained.
Particular attention should be given to supply connections other than direct
connections to the branch circuit (for example, use of power strips).
To install the ears:
1. There are screws that secure each side of the CEN-SWPOE-16 top cover.
Using a #1 or #2 Phillips screwdriver, remove the three screws closest to
the front panel from one side of the unit. Refer to the diagram following
step 3 for a detailed view.
2. Position a rack ear so that its mounting holes align with the holes vacated
by the screws in step 1.
3. Secure the ear to the unit with three screws from step 1, as shown in the
following diagram.
Ear Attachment for Rack Mounting
Use Cover Screws
4. Repeat procedure (steps 1 through 3) to attach the remaining ear to the
opposite side.