Crestron CNX-ASBK Installation Guide Page 9

  • Download
  • Add to my manuals
  • Print
  • Page
    / 12
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 8
Crestron CNX-ASBK Audio Switcher Bussing Kit
19. Daisy-chain the ground wire to each CNX-PAD8.
NOTE: Additional audio patch cords are not required. The bussing cables provide
parallel audio inputs to all of the CNX-PAD8s.
20. Connect the audio RCA cables to the audio inputs and/or audio input
loop-through into their original positions of the original or “primary”
CNX-PAD8.
21. If the configuration of the original CNX-PAD room outputs is to be
kept, reconnect the audio output cables to their original positions.
Connect the audio outputs of the each CNX-PAD8 to their designated
room amplifiers.
22. Connect each 6-pin RJ-11 network device cable to its original position.
23. Using network device cables (not supplied), daisy-chain each
CNX-PAD8 to each other or the control system.
24. At the rear of the CNX-PAD8s, connect the electrical power (4-pin
Cresnet power connectors and/or the external power packs).
Industry Compliance
As of the date of manufacture, this unit has been tested and found to comply with
specifications for CE marking and standards per EMC and Radiocommunications
Compliance Labelling.
Programming Daisy-Chained CNX-PAD8s
The CNX-PAD8s can be programmed to fit any customized installation. Daisy-
chained CNX-PAD8s are programmed individually by using their unique Net IDs.
Refer to the CNX-PAD8 Operations Guide (latest revision of Doc. 8137) for further
information.
Operations & Installation Guide - DOC. 8143 Audio Switcher Bussing Kit: CNX-ASBK 7
Page view 8
1 2 3 4 5 6 7 8 9 10 11 12

Comments to this Manuals

No comments