Crestron SWAMP(I)-24X8 Specifications Page 50

  • Download
  • Add to my manuals
  • Print
  • Page
    / 60
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 49
Sonnex™ Multiroom Audio System Crestron SWAMP(I)-24X8
Uploading and Upgrading
Crestron recommends using the latest programming software and that each device
contains the latest firmware to take advantage of the most recently released features.
However, before attempting to upload or upgrade it is necessary to establish
communication. Once communication has been established, files (for example,
programs or firmware) can be transferred to the control system (and/or device).
Finally, program checks can be performed (such as changing the device ID or
creating an IP table) to ensure proper functioning.
Establishing Communication
Use Crestron Toolbox for communicating with the SWAMP-24X8; refer to the
Crestron Toolbox help file for details. There are three methods of communication:
indirect, USB, and TCP/IP.
Indirect
Indirect Communication
Cresnet
Control System
PC Running
Crestron Toolbox
or USB
Serial,
LAN
SWAMP-24X8
SWAMP-24X8 connects to control system via Cresnet:
1.
Establish communication between the PC and the control system as
described in the latest version of the 2-Series Control Systems Reference
Guide (Doc. 6256).
2.
Use the Address Book in Crestron Toolbox to create an entry for the
SWAMP-24X8 using the expected communication protocol (indirect).
Select the Cresnet ID of the SWAMP-24X8 and the address book entry of
the control system that is connected to the SWAMP-24X8.
3.
Display the SWAMP-24X8’s “System Info” window (click the
icon);
communications are confirmed when the device information is displayed.
USB
NOTE: Required for initial setup of Ethernet parameters.
USB Communication
USB
PC Running
Crestron Toolbox
SWAMP-24X8
The COMPUTER port on the SWAMP-24X8 connects to the USB port on the PC
via the included Type A to Type B USB cable:
1.
Use the Address Book in Crestron Toolbox to create an entry using the
expected communication protocol (USB). When multiple USB devices are
connected, identify the SWAMP-24X8 by entering “SWAMP-24X8” in the
Model textbox, the unit’s serial number in the Serial textbox or the unit’s
hostname in the Hostname textbox. The hostname can be found in the
44 Sonnex™ Multiroom Audio System: SWAMP(I)-24X8 Operations & Installation Guide – DOC. 7049B