Isys
Wired 5.7 Inch Tabletop Touchpanel Crestron TPS-1700
6 Isys
Wired 5.7 Inch Tabletop Touchpanel: TPS-1700 Operations Guide - DOC. 6117
NOTE: When daisy-chaining Cresnet units, strip the ends of the wires carefully to
avoid nicking the conductors. Twist together the ends of the wires that share a pin on
the network connector, and tin the twisted connection. Apply solder only to the ends
of the twisted wires. Avoid tinning too far up the wires or the end becomes brittle.
Insert the tinned connection into the Cresnet connector and tighten the retaining
screw. Repeat the procedure for the other three conductors.
NOTE: For larger networks (i.e., greater than 28 network devices), it may be
necessary to add a Cresnet Hub/Repeater (CNXHUB) to maintain signal quality
throughout the network. Also, for networks with lengthy cable runs, it may be
desirable to add a hub/repeater after only 20 network devices.
Identity Code
Every equipment and user interface within the Cresnet system requires a unique
Cresnet identity code (NET ID). These codes are two-digit hexadecimal numbers
from 03 to FE. Refer to “Select Interface” on page 7 for instructions on setting the
unit’s NET ID. The NET ID of the unit must match the NET ID specified in the
SIMPL Windows program. Refer to “Setting the Net ID in Device Settings” on page
12 for details of the SIMPL Windows procedure.
Configuring the Touchpanel
NOTE: The only connection required to configure the touchpanel is power. Refer to
“Hardware Hookup” on page 9 for details.
MAIN MENU
This menu can also be obtained via
digital reserved join number, 17242.
To configure the unit, it may be necessary to access a series of setup screens prior to
viewing run-time screens that are loaded into the touchpanel for normal operation.
The MAIN MENU for configuring the touchpanel appears when a finger is held
(approx. 5 seconds) to the touchscreen when power is applied.
Upon entering SETUP MODE, the MAIN MENU, shown to the left, displays four
buttons: Touch Screen Calibration, Exit and Run Program, Setup, and
Diagnostics.
Selecting Exit and Run Program verifies that all of the setup information has been
saved to EEPROM and displays the main page that has been programmed into the
touchpanel. The remaining buttons on the MAIN MENU open other menus, which
are discussed in subsequent paragraphs.
Calibration Menu
CALIBRATION MENU
Calibration of the touchscreen is required if the active touch area of a button does
not coincide with the button's image. Select the Touch Screen Calibration
b
utton to
display the CALIBRATION MENU, as shown to the left. The CALIBRATION
MENU offers the choice to initiate calibration with the Perform Calibration button
or return to the previous screen with the Return button. Choose an option by
touching the appropriate button.
If you need to calibrate the touchpanel, the screen displays the message "Touch
Upper Left" centered on the panel with a cross hair in the upper left corner. Touch
the cross hair to initiate calibration. Another message, "Touch Upper Right", appears
with a cross hair in the correct corner. Touch the cross hair. A final message, “Touch
Lower Right”, appears with a cross hair in the correct corner. Touch the crosshair to
finish the calibration and return to the MAIN MENU.