Crestron QM-RMCRX-BA Specifications Page 65

  • Download
  • Add to my manuals
  • Print
  • Page
    / 76
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 64
Crestron QM-RMCRX-BA QuickMedia™ Receiver/Processor
Here the <TrimBand_F> feedback signals may have different values than their
corresponding inputs.
If <RecallTrimPreset> goes high and <TrimPreset#> is set to an invalid value
(out of the 1 to 10 range) all trim settings will be cleared, and all signals will
pass unaffected. This is the same as recalling a trim preset in which every trim
band value is set to 0.
In addition to the 10 trim presets, the QM-RMCRX-BA provides five filter
presets, where a filter preset is a set of six filters. A filter consists of the center
frequency, gain, bandwidth and filter type (EQ, high/low pass, treble/bass shelf)
for each of the three outputs channels. These values are only settable using
SystemBuilder software.
When <RecallFilterPreset> goes high and remains high, the current filter
values stored in <FilterPreset#> (as set in the SystemBuilder software) will be
recalled and applied to the outputs. Valid values for <FilterPreset#> range from
1 to 6.
If <RecallFilterPreset> goes high and <FilterPreset#> is set to an invalid
value (out of the 1 to 6 range) all filters will be cleared, and all signals will pass
unaffected. This is the same as recalling a filter preset in which every filter is set
to 0.
Slot 10: C2I-RMC-FRONTPANEL
The C2I-RMC-FRONTPANEL is the non-programmable front panel of the
QM-RMCRX-BA and other 2-Series control systems. It does not provide an
LCD display or push buttons.
NOTE: The QM-RMCRX-BA does not have a slot 11.
Slot 12: C2I-RX-RY4
The C2I-RX-RY2 provides two isolated relays for controlling low voltage
contact closure devices such as drapes, screens and lifts.
Built-in 2 Low Voltage Isolated Relay Symbol
C2I-RX-RY4 Signals
SIGNAL TYPE
AND NAME
DESCRIPTION
Digital inputs
<A1> and <A2>
Closes the corresponding relay for as long as the
signal remains high. When the signal goes low, the
relay opens.
High/1 (level sensitive) = Close relay
Low/0 = Open relay
Operations Guide – DOC. 6332 QuickMedia™ Receiver/Processor: QM-RMCRX-BA 61